Committer:
Brendan Tollit
-
Date:
2012-02-08 13:08:45 UTC
-
mfrom:
(3892.1.21 p2cv)
-
Revision ID:
brendan.tollit05@imperial.ac.uk-20120208130845-lfqh0zqcet3mroia
Summary:
This merge will permit the use of P2 control volumes for a tetrahedral mesh.
This extends the CV faces routine to add the p2cv tet shape functions.
The method to form the CV mass matrix is then changed to use a sub CV
analytic approach (for p1 and p2 elements one can calculate by hand the
sub CV fraction of the parent element) rather than lumping a FEM mass
matrix. Routines are added to get the cv mass and compute the cv mass.
Everywhere we could find that required a cv mass matrix now calls these
routines. Diagnostic routines to output the CV mass and the lumped FE mass
have been added. The capability to include the density in the
GridReynoldsNumber diagnostic has also been added. These last two
changes are included in the manual.
11 test cases are added (basic, advection, darcy, mmat, mms). A couple
of test cases where changed to not output cv stats as they didnt need it.
This permits p1dgp2 for multimaterial (although may well be buggy linked to
other features) and is known to not work with conservative bounded mesh
to mesh interpolation.
This was worked on by Cian Wilson and myself and reviewed/checked by Axelle.