Fixed bug for double printing the Hirshfeld and Voronoi charges
This happened when the user requested the partial charges and
also LDOS. In those cases the partial charges would be calculated
twice, first correctly, then in-correctly using the LDOS charge.
This is now fixed to *not* print-out the partial charges for the LDOS.