Program Version,EnergyPlus-Windows-64 8.0.0.007, YMD=2013.05.09 19:03,IDD_Version 8.0.0.007
2
 
   ** Warning ** Output:PreprocessorMessage="ExpandObjects" has the following Warning conditions:
3
 
   **   ~~~   ** Warning:  In HVACTemplate:System:VAV "Central VAV" the Heating Coil Design
4
 
   **   ~~~   ** Setpoint is greater than the Preheat Coil Design Setpoint
5
 
   **   ~~~   ** but Heating Coil
6
 
   **   ~~~   ** Type=None. Using Preheat Coil Design Setpoint for the Sizing:System Central
7
 
   **   ~~~   ** Heating Design Supply Air Temperature.
8
 
   ** Warning ** Output:PreprocessorMessage="ExpandObjects" has the following Warning conditions:
9
 
   **   ~~~   ** Warning:  In HVACTemplate:System:VAV "Central VAV" there is no Heating Coil
10
 
   **   ~~~   ** and no Preheat Coil. The Preheat Coil Design Setpoint will be used for the
11
 
   **   ~~~   ** Sizing:System Central Heating Design Supply Air Temperature. This will be
12
 
   **   ~~~   ** the inlet air temperature for sizing reheat coils.
13
 
   ************* Beginning Zone Sizing Calculations
14
 
   ************* Beginning System Sizing Calculations
15
 
   ************* Beginning Plant Sizing Calculations
16
 
   ************* Testing Individual Branch Integrity
17
 
   ************* All Branches passed integrity testing
18
 
   ************* Testing Individual Supply Air Path Integrity
19
 
   ************* All Supply Air Paths passed integrity testing
20
 
   ************* Testing Individual Return Air Path Integrity
21
 
   ************* All Return Air Paths passed integrity testing
22
 
   ************* No node connection errors were found.
23
 
   ************* Beginning Simulation
24
 
   ************* Simulation Error Summary *************
25
 
   ************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Severe Errors.
26
 
   ************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Severe Errors.
27
 
   ************* EnergyPlus Completed Successfully-- 2 Warning; 0 Severe Errors; Elapsed Time=00hr 00min  6.38sec