1
# MSI Z85-G45 Gaming Motherboard
 
2
# 2018, contributed by Leigh Brown
 
3
#
 
4
# dmi: board_name: Z87-G45 GAMING (MS-7821)
 
5
# dmi: board_vendor: MSI
 
6
# dmi: bios_version: V1.4
 
7
# cpu:  Intel(R) Core(TM) i5-4670K CPU @ 3.40GHz
 
8
# driver: nct6775
 
9
 
 
10
chip "nct6779-isa-0a00"
 
11
    label   in0     "VCCIN"
 
12
    compute in0     @*2, @/2
 
13
    set     in0_min 1.4
 
14
    set     in0_max 1.9
 
15
 
 
16
    label   in1     "+5V"
 
17
    compute in1     @*5, @/5
 
18
    set     in1_min 5 * 0.95
 
19
    set     in1_max 5 * 1.05
 
20
 
 
21
    #label   in2     "AVCC"
 
22
    #label   in3     "+3.3V"
 
23
 
 
24
    label   in4     "+12V"
 
25
    compute in4     @*11, @/11
 
26
    set     in4_min 12 * 0.95
 
27
    set     in4_max 12 * 1.05
 
28
 
 
29
    label   in5     "CPUSAV"
 
30
    set     in5_min 0.904 * 0.95
 
31
    set     in5_max 0.904 * 1.05
 
32
 
 
33
    label   in6     "VPCH"
 
34
    set     in6_min 1.05 * 0.95
 
35
    set     in6_max 1.05 * 1.05
 
36
 
 
37
    #label   in7     "3VSB"
 
38
    #label   in8     "Vbat"
 
39
 
 
40
    label   in9     "VCCIOA"
 
41
    set     in9_min 0.97
 
42
    set     in9_max 1.06
 
43
 
 
44
    ignore  in10
 
45
 
 
46
    label   in11     "iGPUV"
 
47
 
 
48
    label   in12     "VCCIOD"
 
49
    set     in12_min 0.97
 
50
    set     in12_max 1.06
 
51
 
 
52
    label   in13     "DRAMV"
 
53
    compute in13     @*2, @/2
 
54
    set     in13_min 1.30
 
55
    set     in13_max 1.80
 
56
 
 
57
    label   in14     "Vcore"
 
58
    set     in14_min 0.4
 
59
    set     in14_max 1.4
 
60
 
 
61
    label   fan2  "CPU Fan"
 
62
    label   fan3  "Chassis Fan 2"
 
63
    label   fan4  "Chassis Fan 1"
 
64
    label   fan1  "Chassis Fan 3"
 
65
    ignore  fan5
 
66
 
 
67
    label   temp1          "System Temp"
 
68
    set     temp1_max      60
 
69
    set     temp1_max_hyst 55
 
70
 
 
71
    label   temp7           "CPU Core Temp"
 
72
 
 
73
    ignore  temp2
 
74
    ignore  temp3
 
75
    ignore  temp4
 
76
    ignore  temp5
 
77
    ignore  temp6
 
78
    ignore  temp8
 
79
    ignore  temp9
 
80
    ignore  temp10
 
81
 
 
82
    ignore  intrusion0
 
83
    ignore  intrusion1