~mmach/netext73/lm-sensors

« back to all changes in this revision

Viewing changes to configs/SuperMicro/X6DH8-XG2.conf

  • Committer: mmach
  • Date: 2020-02-05 20:28:34 UTC
  • Revision ID: netbit73@gmail.com-20200205202834-zc3sla47j9e700w5
3.6

Show diffs side-by-side

added added

removed removed

Lines of Context:
 
1
# Partial and untested configuration file for the SuperMicro X6DH8-XG2.
 
2
# Please report if you try it.
 
3
 
 
4
 
 
5
chip "pc87427-*"
 
6
 
 
7
   label  fan7  "CPU1 Fan"
 
8
   label  fan8  "CPU2 Fan"
 
9
 
 
10
chip "lm93-*"
 
11
 
 
12
   ignore fan1
 
13
   ignore fan2
 
14
   ignore fan3
 
15
   ignore fan4
 
16
 
 
17
   label  in1  "+12V"
 
18
   label  in7  "VCore1"
 
19
   label  in8  "VCore2"
 
20
   label  in9  "+3.3V"
 
21
   label  in10 "+5V"
 
22
   ignore in11
 
23
   label  in15 "-12V"
 
24
 
 
25
   compute in1  @ * ((13.7/1.15)+1), @ / ((13.7/1.15)+1)
 
26
   compute in15 @ * 5.1138 - 13.5771, (@ + 13.5771) / 5.1138
 
27
 
 
28
   label  temp1  "CPU1 Temp"
 
29
   label  temp2  "CPU2 Temp"
 
30
   label  temp3  "Sys Temp"