.SH NAME
3
3
oneac \- Driver for Oneac UPS equipment
4
4
.SH NOTE
5
 
This man page only documents the hardware-specific features of the
 
5
This man page only documents the hardware\(hyspecific features of the
6
6
oneac driver.  For information about the core driver, see
7
7
\fBnutupsdrv\fR(8).
8
 
 
 
8
 
9
9
.SH SUPPORTED HARDWARE
10
 
This driver supports Oneac EG and ON UPS equipment.
 
10
This driver supports Oneac EG and ON UPS equipment with the
 
11
Advanced Interface. If your UPS is equipped with the Basic
 
12
Interface card, use the genericups driver.
11
13
 
12
14
.SH EXTRA ARGUMENTS
13
15
This driver supports the following optional settings in the
14
16
\fBups.conf\fR(5):
15
17
 
16
18
.IP "testtime=\fInum\fR"
17
 
 
18
19
Change battery test time from the 2 minute default.
19
20
 
 
21
.SH INSTANT COMMANDS
 
22
This driver supports the following Instant Commands.
 
23
 
 
24
.IP "reset.input.minmax"
 
25
Reset the minimum and maximum input line voltage values
 
26
seen since the last reset or power on.
 
27
 
 
28
.IP "test.battery.start"
 
29
Start a battery test.  The default time is 2 minutes.  This
 
30
time can be set in the ups.conf file.  See \fBtestime\fR above.
 
31
 
 
32
.IP "test.battery.stop"
 
33
Stops a battery test that is in progress.
 
34
 
 
35
.IP "test.failure.start"
 
36
Starts a 15 second long simulation of an input power
 
37
failure.
 
38
 
20
39
.SH AUTHOR
21
40
Eric Lawson <elawson@inficad.com>
22