.TH POWERMUST 8 "Fri May 14 2004" "" "Network UPS Tools (NUT)" 
 
2
.SH NAME  
 
3
powermust \(hy Driver for Mustek PowerMust series UPS equipment
 
4
.SH NOTE
 
5
This man page only documents the hardware\(hyspecific features of the
 
6
powermust driver. For information about the core driver, see  
 
7
\fBnutupsdrv\fR(8).
 
8
 
 
9
.SH SUPPORTED HARDWARE
 
10
The powermust driver is known to work with the following UPSes:
 
11
 
 
12
    Mustek PowerMust 400VA Plus (12V)
 
13
    Mustek PowerMust 600VA Plus (12V)
 
14
    Mustek PowerMust 800VA Pro (12V)
 
15
    Mustek PowerMust 1000VA Plus (24V)
 
16
    Mustek PowerMust 1400VA Plus (?V)
 
17
    Mustek PowerMust 2000VA USB (?V)
 
18
    OnLite AQUA 50 (12V)
 
19
    Square One Power QP 1000 (?V)
 
20
 
 
21
It may also work with other UPSes in the PowerMust series, but they
 
22
haven't been tested.
 
23
 
 
24
.SH EXTRA ARGUMENTS
 
25
 
 
26
This driver does not support any extra settings in the    
 
27
\fBups.conf\fR(5).
 
28
 
 
29
.SH UPS COMMANDS
 
30
 
 
31
This driver supports some extra commands (see \fBupscmd\fR(8)):
 
32
 
 
33
.IP shutdown.return
 
34
Turn off the load and return when power is back
 
35
 
 
36
.IP shutdown.stayoff
 
37
Turn off the load and remain off
 
38
 
 
39
.IP shutdown.stop
 
40
Stop a shutdown in progress
 
41
 
 
42
.IP load.on
 
43
Turn on the load immediately
 
44
 
 
45
.IP load.off
 
46
Turn off the load immediately
 
47
 
 
48
.IP reset.input.minmax
 
49
Reset minimum and maximum input voltage status
 
50
 
 
51
.SH USER VARIABLES
 
52
 
 
53
The behavior of the driver can be controlled by some user definable
 
54
variables (see \fBupsrw\fR(8)):
 
55
 
 
56
.IP ups.delay.shutdown
 
57
Interval to wait after shutdown with delay command (seconds)
 
58
 
 
59
.IP ups.delay.start
 
60
Interval to wait before (re)starting the load (seconds)
 
61
 
 
62
.SH BUGS
 
63
 
 
64
No known bugs at the moment.
 
65
 
 
66
.SH AUTHOR
 
67
Carlos Rodrigues <carlos.efr@mail.telepac.pt>
 
68
 
 
69
.SH SEE ALSO
 
70
 
 
71
.SS The core driver:
 
72
\fBnutupsdrv\fR(8)
 
73
 
 
74
.SS Internet resources:
 
75
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/