How to Port Open vSwitch to New Software or Hardware
2
====================================================
4
Open vSwitch (OVS) is intended to be easily ported to new software and
5
hardware platforms. This document describes the types of changes that
6
are most likely to be necessary in porting OVS to Unix-like platforms.
7
(Porting OVS to other kinds of platforms is likely to be more
14
For historical reasons, different words are used for essentially the
15
same concept in different areas of the Open vSwitch source tree. Here
16
is a concordance, indexed by the area of the source tree:
21
ofproto/bond.c slave bond
23
lib/netdev.c netdev ---
24
database Interface Port
27
Open vSwitch Architectural Overview
28
-----------------------------------
30
The following diagram shows the very high-level architecture of Open
31
vSwitch from a porter's perspective.
34
| ovs-vswitchd |<-->ovsdb-server
36
| ofproto |<-->OpenFlow controllers
44
Some of the components are generic. Modulo bugs or inadequacies,
45
these components should not need to be modified as part of a port:
47
- "ovs-vswitchd" is the main Open vSwitch userspace program, in
48
vswitchd/. It reads the desired Open vSwitch configuration from
49
the ovsdb-server program over an IPC channel and passes this
50
configuration down to the "ofproto" library. It also passes
51
certain status and statistical information from ofproto back
54
- "ofproto" is the Open vSwitch library, in ofproto/, that
55
implements an OpenFlow switch. It talks to OpenFlow controllers
56
over the network and to switch hardware or software through an
57
"ofproto provider", explained further below.
59
- "netdev" is the Open vSwitch library, in lib/netdev.c, that
60
abstracts interacting with network devices, that is, Ethernet
61
interfaces. The netdev library is a thin layer over "netdev
62
provider" code, explained further below.
64
The other components may need attention during a port. You will
65
almost certainly have to implement a "netdev provider". Depending on
66
the type of port you are doing and the desired performance, you may
67
also have to implement an "ofproto provider" or a lower-level
68
component called a "dpif" provider.
70
The following sections talk about these components in more detail.
73
Writing a netdev Provider
74
-------------------------
76
A "netdev provider" implements an operating system and hardware
77
specific interface to "network devices", e.g. eth0 on Linux. Open
78
vSwitch must be able to open each port on a switch as a netdev, so you
79
will need to implement a "netdev provider" that works with your switch
80
hardware and software.
82
struct netdev_class, in lib/netdev-provider.h, defines the interfaces
83
required to implement a netdev. That structure contains many function
84
pointers, each of which has a comment that is meant to describe its
85
behavior in detail. If the requirements are unclear, please report
88
The netdev interface can be divided into a few rough categories:
90
* Functions required to properly implement OpenFlow features. For
91
example, OpenFlow requires the ability to report the Ethernet
92
hardware address of a port. These functions must be implemented
93
for minimally correct operation.
95
* Functions required to implement optional Open vSwitch features.
96
For example, the Open vSwitch support for in-band control
97
requires netdev support for inspecting the TCP/IP stack's ARP
98
table. These functions must be implemented if the corresponding
99
OVS features are to work, but may be omitted initially.
101
* Functions needed in some implementations but not in others. For
102
example, most kinds of ports (see below) do not need
103
functionality to receive packets from a network device.
105
The existing netdev implementations may serve as useful examples
108
* lib/netdev-linux.c implements netdev functionality for Linux
109
network devices, using Linux kernel calls. It may be a good
110
place to start for full-featured netdev implementations.
112
* lib/netdev-vport.c provides support for "virtual ports"
113
implemented by the Open vSwitch datapath module for the Linux
114
kernel. This may serve as a model for minimal netdev
117
* lib/netdev-dummy.c is a fake netdev implementation useful only
124
After a netdev provider has been implemented for a system's network
125
devices, you may choose among three basic porting strategies.
127
The lowest-effort strategy is to use the "userspace switch"
128
implementation built into Open vSwitch. This ought to work, without
129
writing any more code, as long as the netdev provider that you
130
implemented supports receiving packets. It yields poor performance,
131
however, because every packet passes through the ovs-vswitchd process.
132
See INSTALL.userspace for instructions on how to configure a userspace
135
If the userspace switch is not the right choice for your port, then
136
you will have to write more code. You may implement either an
137
"ofproto provider" or a "dpif provider". Which you should choose
138
depends on a few different factors:
140
* Only an ofproto provider can take full advantage of hardware
141
with built-in support for wildcards (e.g. an ACL table or a
144
* A dpif provider can take advantage of the Open vSwitch built-in
145
implementations of bonding, LACP, 802.1ag, 802.1Q VLANs, and
146
other features. An ofproto provider has to provide its own
147
implementations, if the hardware can support them at all.
149
* A dpif provider is usually easier to implement, but most
150
appropriate for software switching. It "explodes" wildcard
151
rules into exact-match entries (with an optional wildcard mask).
152
This allows fast hash lookups in software, but makes
153
inefficient use of TCAMs in hardware that support wildcarding.
155
The following sections describe how to implement each kind of port.
161
An "ofproto provider" is what ofproto uses to directly monitor and
162
control an OpenFlow-capable switch. struct ofproto_class, in
163
ofproto/ofproto-provider.h, defines the interfaces to implement an
164
ofproto provider for new hardware or software. That structure contains
165
many function pointers, each of which has a comment that is meant to
166
describe its behavior in detail. If the requirements are unclear,
167
please report this as a bug.
169
The ofproto provider interface is preliminary. Please let us know if
170
it seems unsuitable for your purpose. We will try to improve it.
173
Writing a dpif Provider
174
-----------------------
176
Open vSwitch has a built-in ofproto provider named "ofproto-dpif",
177
which is built on top of a library for manipulating datapaths, called
178
"dpif". A "datapath" is a simple flow table, one that is only required
179
to support exact-match flows, that is, flows without wildcards. When a
180
packet arrives on a network device, the datapath looks for it in this
181
table. If there is a match, then it performs the associated actions.
182
If there is no match, the datapath passes the packet up to ofproto-dpif,
183
which maintains the full OpenFlow flow table. If the packet matches in
184
this flow table, then ofproto-dpif executes its actions and inserts a
185
new entry into the dpif flow table. (Otherwise, ofproto-dpif passes the
186
packet up to ofproto to send the packet to the OpenFlow controller, if
189
When calculating the dpif flow, ofproto-dpif generates an exact-match
190
flow that describes the missed packet. It makes an effort to figure out
191
what fields can be wildcarded based on the switch's configuration and
192
OpenFlow flow table. The dpif is free to ignore the suggested wildcards
193
and only support the exact-match entry. However, if the dpif supports
194
wildcarding, then it can use the masks to match multiple flows with
195
fewer entries and potentially significantly reduce the number of flow
196
misses handled by ofproto-dpif.
198
The "dpif" library in turn delegates much of its functionality to a
199
"dpif provider". The following diagram shows how dpif providers fit
200
into the Open vSwitch architecture:
203
| +-------------------+
204
| | ovs-vswitchd |<-->ovsdb-server
205
| +-------------------+
206
| | ofproto |<-->OpenFlow controllers
207
| +--------+-+--------+ _
208
| | netdev | |ofproto-| |
209
userspace | +--------+ | dpif | |
210
| | netdev | +--------+ |
211
| |provider| | dpif | |
212
| +---||---+ +--------+ |
213
| || | dpif | | implementation of
214
| || |provider| | ofproto provider
217
_ +---||-----+---||---+ |
219
kernel | | +--------+ _|
221
|_ +--------||---------+
226
struct dpif_class, in lib/dpif-provider.h, defines the interfaces
227
required to implement a dpif provider for new hardware or software.
228
That structure contains many function pointers, each of which has a
229
comment that is meant to describe its behavior in detail. If the
230
requirements are unclear, please report this as a bug.
232
There are two existing dpif implementations that may serve as
233
useful examples during a port:
235
* lib/dpif-linux.c is a Linux-specific dpif implementation that
236
talks to an Open vSwitch-specific kernel module (whose sources
237
are in the "datapath" directory). The kernel module performs
238
all of the switching work, passing packets that do not match any
239
flow table entry up to userspace. This dpif implementation is
240
essentially a wrapper around calls into the kernel module.
242
* lib/dpif-netdev.c is a generic dpif implementation that performs
243
all switching internally. This is how the Open vSwitch
244
userspace switch is implemented.
250
Open vSwitch source code uses uint16_t, uint32_t, and uint64_t as
251
fixed-width types in host byte order, and ovs_be16, ovs_be32, and
252
ovs_be64 as fixed-width types in network byte order. Each of the
253
latter is equivalent to the one of the former, but the difference in
254
name makes the intended use obvious.
256
The default "fail-mode" for Open vSwitch bridges is "standalone",
257
meaning that, when the OpenFlow controllers cannot be contacted, Open
258
vSwitch acts as a regular MAC-learning switch. This works well in
259
virtualization environments where there is normally just one uplink
260
(either a single physical interface or a bond). In a more general
261
environment, it can create loops. So, if you are porting to a
262
general-purpose switch platform, you should consider changing the
263
default "fail-mode" to "secure", which does not behave this way. See
264
documentation for the "fail-mode" column in the Bridge table in
265
ovs-vswitchd.conf.db(5) for more information.
267
lib/entropy.c assumes that it can obtain high-quality random number
268
seeds at startup by reading from /dev/urandom. You will need to
269
modify it if this is not true on your platform.
271
vswitchd/system-stats.c only knows how to obtain some statistics on
272
Linux. Optionally you may implement them for your platform as well.
275
Why OVS Does Not Support Hybrid Providers
276
-----------------------------------------
278
The "Porting Strategies" section above describes the "ofproto
279
provider" and "dpif provider" porting strategies. Only an ofproto
280
provider can take advantage of hardware TCAM support, and only a dpif
281
provider can take advantage of the OVS built-in implementations of
282
various features. It is therefore tempting to suggest a hybrid
283
approach that shares the advantages of both strategies.
285
However, Open vSwitch does not support a hybrid approach. Doing so
286
may be possible, with a significant amount of extra development work,
287
but it does not yet seem worthwhile, for the reasons explained below.
289
First, user surprise is likely when a switch supports a feature only
290
with a high performance penalty. For example, one user questioned why
291
adding a particular OpenFlow action to a flow caused a 1,058x slowdown
292
on a hardware OpenFlow implementation [1]. The action required the
293
flow to be implemented in software.
295
Given that implementing a flow in software on the slow management CPU
296
of a hardware switch causes a major slowdown, software-implemented
297
flows would only make sense for very low-volume traffic. But many of
298
the features built into the OVS software switch implementation would
299
need to apply to every flow to be useful. There is no value, for
300
example, in applying bonding or 802.1Q VLAN support only to low-volume
303
Besides supporting features of OpenFlow actions, a hybrid approach
304
could also support forms of matching not supported by particular
305
switching hardware, by sending all packets that might match a rule to
306
software. But again this can cause an unacceptable slowdown by
307
forcing bulk traffic through software in the hardware switch's slow
308
management CPU. Consider, for example, a hardware switch that can
309
match on the IPv6 Ethernet type but not on fields in IPv6 headers. An
310
OpenFlow table that matched on the IPv6 Ethernet type would perform
311
well, but adding a rule that matched only UDPv6 would force every IPv6
312
packet to software, slowing down not just UDPv6 but all IPv6
315
[1] Aaron Rosen, "Modify packet fields extremely slow",
316
openflow-discuss mailing list, June 26, 2011, archived at
317
https://mailman.stanford.edu/pipermail/openflow-discuss/2011-June/002386.html.
323
Please direct porting questions to dev@openvswitch.org. We will try
324
to use questions to improve this porting guide.