~ubuntu-branches/ubuntu/precise/linux-lowlatency/precise

« back to all changes in this revision

Viewing changes to Documentation/hwmon/acpi_power_meter

  • Committer: Package Import Robot
  • Author(s): Alessio Igor Bogani
  • Date: 2011-10-26 11:13:05 UTC
  • Revision ID: package-import@ubuntu.com-20111026111305-tz023xykf0i6eosh
Tags: upstream-3.2.0
ImportĀ upstreamĀ versionĀ 3.2.0

Show diffs side-by-side

added added

removed removed

Lines of Context:
 
1
Kernel driver power_meter
 
2
=========================
 
3
 
 
4
This driver talks to ACPI 4.0 power meters.
 
5
 
 
6
Supported systems:
 
7
  * Any recent system with ACPI 4.0.
 
8
    Prefix: 'power_meter'
 
9
    Datasheet: http://acpi.info/, section 10.4.
 
10
 
 
11
Author: Darrick J. Wong
 
12
 
 
13
Description
 
14
-----------
 
15
 
 
16
This driver implements sensor reading support for the power meters exposed in
 
17
the ACPI 4.0 spec (Chapter 10.4).  These devices have a simple set of
 
18
features--a power meter that returns average power use over a configurable
 
19
interval, an optional capping mechanism, and a couple of trip points.  The
 
20
sysfs interface conforms with the specification outlined in the "Power" section
 
21
of Documentation/hwmon/sysfs-interface.
 
22
 
 
23
Special Features
 
24
----------------
 
25
 
 
26
The power[1-*]_is_battery knob indicates if the power supply is a battery.
 
27
Both power[1-*]_average_{min,max} must be set before the trip points will work.
 
28
When both of them are set, an ACPI event will be broadcast on the ACPI netlink
 
29
socket and a poll notification will be sent to the appropriate
 
30
power[1-*]_average sysfs file.
 
31
 
 
32
The power[1-*]_{model_number, serial_number, oem_info} fields display arbitrary
 
33
strings that ACPI provides with the meter.  The measures/ directory contains
 
34
symlinks to the devices that this meter measures.
 
35
 
 
36
Some computers have the ability to enforce a power cap in hardware.  If this is
 
37
the case, the power[1-*]_cap and related sysfs files will appear.  When the
 
38
average power consumption exceeds the cap, an ACPI event will be broadcast on
 
39
the netlink event socket and a poll notification will be sent to the
 
40
appropriate power[1-*]_alarm file to indicate that capping has begun, and the
 
41
hardware has taken action to reduce power consumption.  Most likely this will
 
42
result in reduced performance.
 
43
 
 
44
There are a few other ACPI notifications that can be sent by the firmware.  In
 
45
all cases the ACPI event will be broadcast on the ACPI netlink event socket as
 
46
well as sent as a poll notification to a sysfs file.  The events are as
 
47
follows:
 
48
 
 
49
power[1-*]_cap will be notified if the firmware changes the power cap.
 
50
power[1-*]_interval will be notified if the firmware changes the averaging
 
51
interval.